VUTLAN Products |
|
Server Rooms Monitoring Systems |
|
VUTLAN provides IP monitoring and power management solutions for enterprises and small businesses. Monitoring Systems and IP Power Distribution ranges are designed for large data centres, server rooms, web hosting facilities, 19 inch telecommunication racks etc. Environmental monitoring in the server rooms, on the telecommunication nodes, in data centers et cetera is of great importance to many if not to all companies. What are the indoor temperature and humidity, what happens to the air conditioning or fans, whether the line voltage has a huge impact on the reliability of the equipment and the service life of servers, switches, and routers. If you have the only rack with a couple of ups and two three servers, you need to install a small monitoring unit with 5-6 sensors, enter your notifications and logic and may be to connect an inexpensive USB cam. Built-in web server and video server allows you to view logs and events at your facility, the logic when properly installed will allow the monitoring system to accept most decisions, for example, to shut down servers at high temperature or at failure of air conditioning or fans, or in case of fire, etc. and to warn user with any notification or SMS (if GSM modem is installed). If you have a set of facilities and requires a scalable, easy-to-install solution for monitoring a distributed network, then you must either apply extension units and sensors that allow to gather information from wide area, or when there are absolutely great distances between nodes and objects, it is possible to use SNMP applications that allow to collect information from multiple remote sites and can be stored in any database, if necessary, to use this information by appropriate authorities. It is also important to use monitoring systems with easy scalability and a wide range of sensors,with longlife-warranty period at a reasonable prices. All this ensures the equipment from VUTLAN, the most modern manufacturer of IP monitoring systems! Manufacturer's website: http://www.vutlan.com |
| REMOTE CONTROL | |
|---|---|
| IP monitoring |
Web, SNMP, manual SMS (GSM modem art. VT7670 #03133 is ordered separately!) |
| Sensors control | Administrative 3-level control of sensors using login |
| INTERFACE & PROTOCOL SUPPORT | |
| Interface | Access via any Internet browser. |
| LAN | Ethernet 10/100Mbit |
| Network protocols |
HTTP; HTTPS; DynDNS; SSL; SNMP v1, v2c, v3; SMTP; FTP; Syslog; RADIUS; OpenVPN |
| OS | Linux 6.2 |
| Processor | dual-core CortexTM-A7 720 MHz / 128 MB |
| Software | Built-in software for events processing. |
| Alert type |
FTP, syslog, SMTP or SNMP, SMS (LTE modem art. VT7670 #03133 is ordered separately!) |
| Pings | Built-in ping |
| LEDs |
STATUS, E1, E2, ERR, 4x OUTLET |
| Clock | Built-in clock with time synchronization |
| Watchdog | Built-in watchdog timer |
| POWER | |
| Power input | IEC C20 240V x 16A. Fuse protection. |
| Power output | 8x C13 240V |
| Power consumption | 10W |
| INPUTS/OUTPUTS | |
| Ethernet | 100Mbit |
| Mini USB AB | USB 2.0 HS |
| Analog port | 2x 6P4C for connection of any analog sensor. |
| CAN BUS | 1 x 6P6C for connection of up to 32 CAN sensors on each BUS. |
| Relay outputs | 8x C13 230V/10A power sockets |
| Built-in sensors |
Temperature sensor (1%), Power supply voltage sensor (1%) |
| Dry contacts input | x2 |
| 12V outlets | 2x 0.25A |
| EXTERNAL MEMORY | |
| Micro SD card |
Micro SD card slot (SDXC up to 512 Gb - saving logs, record video, run software, databases and scripts) |
| FEATURES | |
| Installation | 19" cabinet |
| Dimensions | (LxHxW) 440 x 44.45 (1U) x 79 mm |
| Operating characteristics |
Humidity - Min. 5% - Max. 95% (Non-Condensing), Temperature - Min. -10° C - Max.80° C |
| Net weight | 1,5 kg |
| Supply includes |
EU Schuko C20 0.75 мм2 230V 10A cable, 2x IEC C13 Socket to IEC C14 Plug Power Cord, Self-adhesive rubber foot 4 pcs, Warranty card, Short description and connection guide, Patch cable RJ-45 1m, Terminal plug 3 pins 3.5mm 1pcs, Terminal plug 3 pins 3.81mm 1pcs, Terminal plug 2 pins 3.81mm 1pc, 19" mounting brackets 2pcs, Screws 6pcs M3 8mm |
| Warranty | 3 years |
| Connection |
Plug 220V is put into the outlet necessary for measurement of 220V. Cable's USB connector must be connected to the USB output, connector RJ-11 must be connected to an analog input of any system unit. Determination of sensor's type and connection occur automatically. |
|---|---|
| Set includes | Sensor and USB RJ-11 patch cable (1.8 m). |
| Voltage measured | 90-250V |
| Accuracy of measurement | 2% |
| Max. distance m | 100m |
| Net weight | 125g |
| Dimensions (LHW) | 63×66×40mm |
| Installation |
Using patch-cable RJ-11 the sensor is connected to an analog input of any system unit. Determination of sensor's type and connection occur automatically. One of devices in the kit, for example, magnet, is mounted on a door; the second device is mounted on a jamb of a door. At opening a door contact is disconnected, and system of monitoring receives notification on opening. The first sensor is connected using patch-cable RJ-11 to an analog input of the system unit, the consequent sensor is connected via patch-cable RJ-11 to an output of the first sensor and so on. |
|---|---|
| Set includes |
Contact sensor, magnet, 4-wired patch cable RJ-11 (2m), two screws 4.8×16mm, 2 screws M5 and 2 nuts, bracket, double sided sticker. |
| Max. distance | 150m |
| Net weight | 106g |
| Dimensions (LHW) | Two compact devices with dimensions 60×18×18mm |
| Voltage measured | 0-75V |
|---|---|
| Accuracy of measurement | 1% |
| Max. distance m | 50m |
| Net weight | 100g |
| Dimensions (LHW) | 60×18×18 mm |
| Voltage measured | 0-246V AC |
|---|---|
| Accuracy of measurement | 1% |
| Max. distance m | 100m |
| Net weight | 125g |
| Dimensions (HxWxD) | 90.2×36.3×57.5mm |
| Technical specifications | |
|---|---|
| Technology | Laser scattering based on contamination-resistance technology with optical particle counters (OPCs) |
| Mass concentration precision | ±10 % |
| Mass concentration range | 0 - 1000 μg/m³ |
| Lifetime | more than 10 years |
| Particle size range | 0.3 to 10.5 μm |
| Best used in temperatures | from +10° С to +40°C |
| Best used in humidity | from 20% RH to 80% RH |
| Operating Temperature | -10 to +60°C |
| Operating humidity | 0 to 95% RH |
| Cable length | 2m |
| Output terminal | x1 RJ-11, 6p4c |
| Max distance | 50m |
| Certification standards | MCERTS-certified |
| Technical specifications | |
|---|---|
| Measured humidity range | 10-95% RH |
| Accuracy | 5%RH |
| Working temperature | -10 .. +80°C |
| Features | |
| Installation | On the bottom there is a ledge with Ø4.5mm and height 1mm and a Ø5mm mounting hole fpr mounting the sensor. |
| 5mm from it for fastening the sensor using 4.8×16 mm screw. | |
| Connection | Humidity sensor contains RJ-11 jack and is connected to an analog input of any system unit. Determination of type of sensor and connection occur automatically. |
| Supply includes |
Sensor, 4-wired patch cable RJ11 (2m), 4.8×16mm screw, double sided sticker. |
| Net weight | 60g |
| Dimensions | 60×18×18mm |
| Max distance | 150m |
| Technical specifications | |
|---|---|
| Operating temperature | -50...+105°C |
| Accuracy | 3°C |
| Max. distance | 100m |
| Features | |
| Installation |
An all-weather 2-pair UTP cable of 15m emerges from the cylinder. After installation of cylinder outside of a building, the cable must be placed to reach the system unit. |
| Connection | After installation RJ-11 connector is connected to an analog input of any system unit. Determination of type of sensor and connection occur automatically. |
| Supply includes | 4-wired cable RJ11 (15m) with sensor head |
| Net weight | 340g |
| Dimensions (LHW) | Device has a shape of a Ø7×23mm cylinder |
| Technical specifications | |
|---|---|
| Detection angle | 120° |
| Sensing distance | maximum is 8 meters |
| Frequency Range | 5.725GHz-5.875GHz |
| Max. detection distance | 100 m |
| Features | |
| Installation | On the bottom there is a mounting slot for fastening the sensor with a plastic bracket. |
| Connection |
Motion sensor contains RJ-11 jack and is connected to an analog input of any system unit. Determination of sensor's type and connection occur automatically. To adjust sensitivity, read manual. To change cable connection, open the cover and read manual. |
| Supply includes |
Sensor, cable RJ11 4m, holder |
| Technical specifications | |
|---|---|
| Sensitivity | 0,05 - 0,2 db/m |
| Features | |
| Installation | On the bottom there are Ø5mm mounting holes for fastening the smoke sensor to the surface by 4.8×20mm screws or/and bracket and M4 screws. |
| Connection |
Detector's jack RJ-11 is connected to an analog input of any system unit using patch-cable RJ-11. Determination of the sensor's type and connection occur automatically. The monitoring system allows to connect several smoke detectors into a linear circuit. For this purpose each detector has two jacks RJ-11 input and output. The first is connected to an analog input of the system unit using a patch-cable RJ-11, the consequent is connected via patch-cable RJ-11 to an output of the first detector and so on. as one sensor with one address. |
| Supply includes |
Detector, 4-wired cable RJ11 (2m), 2 screws and 2 nuts M4, 2 screws 4.8×20mm, bracket, double sided sticker. |
| Net weight | 290g |
| Dimensions (LHW) | Ø100×45 |
| Max distance | 150m |