[-]remove#02330 |
[-]remove#04252 |
[-]remove#04383 |
[-]remove#04267 |
[-]remove#04362 |
[-]remove#04269 |
[-]remove#04392 |
[-]remove#08397 |
[-]remove#08343 |
Coaxial ratchet crimping tool (AT-336K) |
Coaxial ratchet crimping tool (Hanlong HT-336I) |
Replacement die (Hanlong HT-3I) |
Replacement die (Hanlong HT-2E) |
Compression crimping tool for F, BNC & RCA compression connectors with adjustment for crimping different length of connectors (Hanlong HT-H510B) |
Replacement die (Hanlong HT-3J) |
Ratchet crimping tool, frame only (Hanlong HT-336FM) |
Power supply 120W 48VDC, DIN TS35, P.F.C. (Mean Well SDR-120-48) |
Compression crimping tool for F type compression connectors (AT-H548A) |
Crimping diameter |
2.54 mm, 3.25 mm, 10.9 mm
|
1.70 mm, 2.36 mm, 5.36 mm, 6.46 mm, 8.00 mm
|
6,46mm, 5,36mm, 2,36mm, 1,70mm, 8,00mm
|
-
|
-
|
1,07mm, 1,72mm, 1,98mm, 3,25mm, 3,84mm, 4,52mm
|
-
|
-
|
-
|
Purpose |
-
|
-
|
-
|
insulated connectors, non-insulated connectors
|
F;BNC;RCA type compression connectors, angular connectors
|
-
|
connectors depending on the chosen input
|
-
|
F type compression connectors
|
Connector types |
LC
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Manufacturer |
-
|
-
|
-
|
-
|
-
|
-
|
Hanlong |
-
|
-
|
Cable types |
RG8, RG11, RG174, RG213, H1000, CNT400, FIBER OPTIC |
RG6, RG58, RG59, H155, H-RF5, RF-5, RF-240.
|
RG58, RG59, RG6, H155, RG174 |
0,50mm2 (AWG 22), 0,75mm2 (AWG 20), 1,0mm2 (AWG 18), 1,5mm2 (AWG 16), 2,5mm2 (AWG 14), 4,0mm2 (AWG 12)
|
RG59/RG6; RG11
|
RG122, RG174, RG179, RG180, RG187, RG188, RG195, RG178, RG316, BELDEN 8218, FIBER OPTIC |
-
|
-
|
RG59/RG6, RG11
|
Packaging |
-
|
-
|
-
|
-
|
Blister pack
|
-
|
Blister pack
|
-
|
Blister pack |
Arms |
-
|
-
|
-
|
#04392 Ratchet crimping tool, frame only (Hanlong HT-336FM)
|
-
|
-
|
-
|
-
|
-
|
Manufacturer's markings |
-
|
HT-336I, HT-5133I |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Connector length for RG59/RG6 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
15,5 ÷ 22,6 mm
|
Producer |
-
|
-
|
-
|
Hanlong |
Hanlong |
-
|
-
|
-
|
-
|
Connector length for RG11 |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
30,5 ÷ 37,3 mm
|
Environment |
Working temperature |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-25°C ÷ 70°C
|
-
|
Working humidity |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
20÷95% RH non-condensing
|
-
|
Storage temperature |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-40°C ÷ 85°C
|
-
|
Storage Humidity |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
10÷95% RH
|
-
|
Temperature coefficient |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
±0.03%/°C (0÷50°C)
|
-
|
Vibration (component) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
-
|
Vibration (mounting) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
compliance to IEC60068-2-6
|
-
|
Input |
Voltage range |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
88÷264VAC, 124÷370VDC
|
-
|
Frequency range |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
47÷63Hz
|
-
|
Power factor (typ.) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0.93/230VAC at full load, 0.96/115VAC at full load
|
-
|
Efficiency (typ.) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
90.5%
|
-
|
AC current (typ.) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
1.4A/115VAC, 0.7A/230VAC
|
-
|
Inrush current (typ.) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
35A/115VAC cold start, 70A/230VAC cold start
|
-
|
Leakage current |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
<1mA/240VAC
|
-
|
Others |
MTBF |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
min. 289900h MIL-HDBK-217F (25°C)
|
-
|
Dimension (W x H x D) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
40mm x 125,2mm x 113,5mm
|
-
|
Weight |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0,67kg |
-
|
Output |
DC Voltage |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
48V
|
-
|
Rated current |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
2.5A
|
-
|
Current Range |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
0÷2.5A
|
-
|
Rated Power |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
120W
|
-
|
Ripple & noise (max.) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
120mVp-p
|
-
|
Voltage adjustment range |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
48÷55V
|
-
|
Voltage tolerance |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
±1.0%
|
-
|
Line regulation |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
±0.5%
|
-
|
Load regulation |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
±1.0%
|
-
|
Setup & rise time |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
1500ms & 60ms/230VAC at full load, 3000ms & 40ms/115VAC at full load
|
-
|
Hold up time (typ.) |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
20ms/230VAC at full load, 20ms/115VAC at full load
|
-
|
Protection |
Overload |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
110%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed
|
-
|
Overvoltage |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
56÷65V, protection type - shut down o/p voltage & re-power on to recover
|
-
|
Over temperature |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
95°C ±5°C (TSW1) detect on heatsink of power transistor, protection type - shut down o/p voltage & re-power on to recover
|
-
|
Safety & EMC |
Safety standards |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
UL508, UL60950-1, TUV EN60950-1
|
-
|
Withstand voltage |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC
|
-
|
Isolation resistance |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC
|
-
|
EMI conduction & radiation |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
EN55011, EN55022 (CISPR22), EN61204-3 Class B
|
-
|
Harmonic current |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
EN61000-3-2, EN61000-3-3
|
-
|
EMS immunity |
-
|
-
|
-
|
-
|
-
|
-
|
-
|
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level criteria A
|
-
|
Net Price |
9.66 USD |
19.30 USD |
6.34 USD |
6.00 USD |
28.30 USD |
6.34 USD |
14.90 USD |
58.50 USD |
15.30 USD |
« return to products list |