[-]remove#02307 |
[-]remove#02231 |
[-]remove#04390 |
[-]remove#08399 |
Universal fiber optic stripper (Hanlong HTS-144H) |
Coaxial hex crimping tool (Hanlong HT-106E) |
Replacement blade (Hanlong HT-RB0809C) |
Power supply 240W 48VDC, DIN TS35, P.F.C. (Mean Well SDR-240-48) |
Crimping diameter |
-
|
5.40 mm, 8.20 mm, 11.4 mm
|
-
|
-
|
Dimentions |
-
|
-
|
11x10.5mm, 14x11.5mm, 21x10.5mm
|
-
|
Hole diameters |
glass cladding 250->125µm, buffer insulation 900->250µm, outer PVC jacket 2-3 mm
|
-
|
-
|
-
|
Cable types |
-
|
RG6, RG11, RG58, RG213 |
-
|
-
|
Quantity |
-
|
-
|
6pcs. (2pcs. of each size) |
-
|
Packaging |
Blister
|
-
|
-
|
-
|
Producer |
Hanlong |
-
|
-
|
-
|
Environment |
Working temperature |
-
|
-
|
-
|
-25°C ÷ 70°C
|
Working humidity |
-
|
-
|
-
|
20÷95% RH non-condensing
|
Storage temperature |
-
|
-
|
-
|
-40°C ÷ 85°C
|
Storage Humidity |
-
|
-
|
-
|
10÷95% RH
|
Temperature coefficient |
-
|
-
|
-
|
±0.03%/°C (0÷50°C)
|
Vibration (component) |
-
|
-
|
-
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
Vibration (mounting) |
-
|
-
|
-
|
compliance to IEC60068-2-6
|
Input |
Voltage range |
-
|
-
|
-
|
88÷264VAC, 124÷370VDC
|
Frequency range |
-
|
-
|
-
|
47÷63Hz
|
Power factor (typ.) |
-
|
-
|
-
|
0.93/230VAC at full load, 0.96/115VAC at full load
|
Efficiency (typ.) |
-
|
-
|
-
|
94%
|
AC current (typ.) |
-
|
-
|
-
|
2.6A/115VAC, 1.3A/230VAC
|
Inrush current (typ.) |
-
|
-
|
-
|
33A/115VAC cold start, 65A/230VAC cold start
|
Leakage current |
-
|
-
|
-
|
<1mA/240VAC
|
Others |
MTBF |
-
|
-
|
-
|
min. 169300h MIL-HDBK-217F (25°C)
|
Dimension (W x H x D) |
-
|
-
|
-
|
63mm x 125,2mm x 113,5mm
|
Weight |
-
|
-
|
-
|
1,03kg |
Output |
DC Voltage |
-
|
-
|
-
|
48V
|
Rated current |
-
|
-
|
-
|
5A
|
Current Range |
-
|
-
|
-
|
0÷5A
|
Rated Power |
-
|
-
|
-
|
240W
|
Ripple & noise (max.) |
-
|
-
|
-
|
120mVp-p
|
Voltage adjustment range |
-
|
-
|
-
|
48÷55V
|
Voltage tolerance |
-
|
-
|
-
|
±1.0%
|
Line regulation |
-
|
-
|
-
|
±0.5%
|
Load regulation |
-
|
-
|
-
|
±1.0%
|
Setup & rise time |
-
|
-
|
-
|
1500ms & 60ms/230VAC at full load, 3000ms & 40ms/115VAC at full load
|
Hold up time (typ.) |
-
|
-
|
-
|
20ms/230VAC at full load, 20ms/115VAC at full load
|
Protection |
Overload |
-
|
-
|
-
|
110%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed
|
Overvoltage |
-
|
-
|
-
|
56÷65V, protection type - shut down o/p voltage & re-power on to recover
|
Over temperature |
-
|
-
|
-
|
95°C ±5°C (TSW1) detect on heatsink of power transistor, protection type - shut down o/p voltage & re-power on to recover
|
Safety & EMC |
Safety standards |
-
|
-
|
-
|
UL508, UL60950-1, TUV EN60950-1
|
Withstand voltage |
-
|
-
|
-
|
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC
|
Isolation resistance |
-
|
-
|
-
|
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC
|
EMI conduction & radiation |
-
|
-
|
-
|
EN55011, EN55022 (CISPR22), EN61204-3 Class B
|
Harmonic current |
-
|
-
|
-
|
EN61000-3-2, EN61000-3-3
|
EMS immunity |
-
|
-
|
-
|
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level criteria A
|
Net Price |
11.00 USD |
13.40 USD |
2.20 USD |
121.00 USD |
« return to products list |