| [-]remove#08433 |
[-]remove#02302 |
[-]remove#06676 |
[-]remove#07785 |
| Unmanaged switch, 4x 10/1000 RJ-45 PoE, 1x 10/1000 RJ-45, 1x 1000 SFP socket, slim housing (ORing IGPS-1411GTP-24V) |
Modular crimping tool 4p+6p+8p (AT-2008R) |
Power supply 40W 24VDC, mini, DIN TS35 (Mean Well MDR-40-24) |
Modular crimping tool 8p (AT-L2182R) |
| Purpose |
-
|
modular plugs RJ50 (10p), modular computer plugs RJ45 (8p8c), modular telephone plugs (6p6c; 6p4c; 6p2c), 6p6c modular DEC type plugs, RJ9 modular headphone plugs (4p4c; 4p2c)
|
-
|
RJ45 modular computer plugs (8p8c)
|
| Additional functions |
-
|
Cutter and stripper for flat wires, inbuilt return block mechanism.
|
-
|
cutter and wire stripper, arm return lock
|
| Replaceable blades |
-
|
yes
|
-
|
yes
|
| Arms length |
-
|
20.3 cm
|
-
|
-
|
| Packaging |
-
|
-
|
-
|
Blister pack |
| Packagnig |
-
|
Blister pack |
-
|
-
|
| DIP-Switch |
| DIP-Switch 1 |
Power-1 failed warning - (ON) enable, (OFF) disable
|
-
|
-
|
-
|
| DIP-Switch 2 |
Power-2 failed warning - (ON) enable, (OFF) disable
|
-
|
-
|
-
|
| Environment |
| Working temperature |
-
|
-
|
-20°C ÷ 70°C
|
-
|
| Working humidity |
-
|
-
|
20÷90% RH non-condensing
|
-
|
| Storage temperature |
-
|
-
|
-40°C ÷ 85°C
|
-
|
| Storage Humidity |
-
|
-
|
10÷95% RH
|
-
|
| Temperature coefficient |
-
|
-
|
±0.03%/°C (0÷50°C)
|
-
|
| Vibration (component) |
-
|
-
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
-
|
| Vibration (mounting) |
-
|
-
|
compliance to IEC60068-2-6
|
-
|
| Environmental |
| Storage Temperature |
-40÷85°C (-40÷185°F)
|
-
|
-
|
-
|
| Operating Temperature |
-40÷60°C (-40÷140°F)
|
-
|
-
|
-
|
| Operating Humidity |
5%÷95% Non-condensing
|
-
|
-
|
-
|
| Fault contact |
| Relay |
Relay output to carry capacity of 1A at 24VDC
|
-
|
-
|
-
|
| Function |
| DC OK signal relay contact rating (max.) |
-
|
-
|
30V/1A resistive
|
-
|
| Input |
| Voltage range |
-
|
-
|
85÷264VAC, 120÷370VDC
|
-
|
| Frequency range |
-
|
-
|
47÷63Hz
|
-
|
| Efficiency (typ.) |
-
|
-
|
88%
|
-
|
| AC current (typ.) |
-
|
-
|
1.1A/115VAC, 0.7A/230VAC
|
-
|
| Inrush current (typ.) |
-
|
-
|
30A/115VAC cold start, 60A/230VAC cold start
|
-
|
| Leakage current |
-
|
-
|
<1mA/240VAC
|
-
|
| LED Indicators |
| Power indicator |
Green - Power LED x 2
|
-
|
-
|
-
|
| Fault indicator |
Amber - Indicate PWR1 or PWR2 failure
|
-
|
-
|
-
|
| 10/100/1000Base-T(X) RJ45 port indicator and PoE Indicator (P1÷P4) |
Green for port Link/Act., Green for power injected
|
-
|
-
|
-
|
| 10/100/1000Base-T(X) RJ45 port Indicator (P5) |
Green for port Link/Act., Amber for 100Mbps Indicator
|
-
|
-
|
-
|
| 100/1000Base-X SFP port indicator |
Green for port Link/Act.
|
-
|
-
|
-
|
| Others |
| MTBF |
-
|
-
|
min. 301700h MIL-HDBK-217F (25°C)
|
-
|
| Dimension (W x H x D) |
-
|
-
|
40mm x 90mm x 100mm
|
-
|
| Weight |
-
|
-
|
0.3kg |
-
|
| Output |
| DC Voltage |
-
|
-
|
24V
|
-
|
| Rated current |
-
|
-
|
1.7A
|
-
|
| Current Range |
-
|
-
|
0÷1.7A
|
-
|
| Rated Power |
-
|
-
|
40.8W
|
-
|
| Ripple & noise (max.) |
-
|
-
|
150mVp-p
|
-
|
| Voltage adjustment range |
-
|
-
|
24÷30V
|
-
|
| Voltage tolerance |
-
|
-
|
±1.0%
|
-
|
| Line regulation |
-
|
-
|
±1.0%
|
-
|
| Load regulation |
-
|
-
|
±1.0%
|
-
|
| Setup & rise time |
-
|
-
|
500ms & 30ms/230VAC at full load, 500ms & 30ms/115VAC at full load
|
-
|
| Hold up time (typ.) |
-
|
-
|
50ms/230VAC at full load, 20ms/115VAC at full load
|
-
|
| Physical Characteristic |
| Enclosure |
IP-30
|
-
|
-
|
-
|
| Dimension (W x D x H) |
41 (W) x 94.9 (D) x 144.3(H) mm
|
-
|
-
|
-
|
| Weight |
580 g
|
-
|
-
|
-
|
| Physical Ports |
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX with PoE+ (P.S.E.) |
4
|
-
|
-
|
-
|
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX |
1
|
-
|
-
|
-
|
| 100/1000Base-X SFP port |
1
|
-
|
-
|
-
|
| Power |
| Input power |
Dual DC inputs. 12~36VDC on 6-pin terminal block
|
-
|
-
|
-
|
| Power consumption (typical) |
6.5W
|
-
|
-
|
-
|
| Overload current protection |
present
|
-
|
-
|
-
|
| Reverse polarity protection |
not present
|
-
|
-
|
-
|
| Protection |
| Overload |
-
|
-
|
105%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed
|
-
|
| Overvoltage |
-
|
-
|
31.2÷36V, protection type - shut down o/p voltage & re-power on to recover
|
-
|
| Regulatory approvals |
| EMI |
FCC Part 15, CISPR (EN55022) class A
|
-
|
-
|
-
|
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
|
-
|
-
|
-
|
| Shock |
IEC60068-2-27
|
-
|
-
|
-
|
| Free Fall |
IEC60068-2-32
|
-
|
-
|
-
|
| Vibration |
IEC60068-2-6
|
-
|
-
|
-
|
| Safety |
EN60950-1
|
-
|
-
|
-
|
| Safety & EMC |
| Safety standards |
-
|
-
|
UL508, UL60950-1, TUV EN60950-1, NEC class 2 / LPS
|
-
|
| Withstand voltage |
-
|
-
|
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC
|
-
|
| Isolation resistance |
-
|
-
|
I/P-O/P 100MΩ/500VDC 25°C 70%RH, I/P-FG 100MΩ/500VDC 25°C 70%RH, O/P-FG 100MΩ/500VDC 25°C 70%RH
|
-
|
| EMI conduction & radiation |
-
|
-
|
EN55011, EN55022 (CISPR22), EN61204-3 Class B
|
-
|
| Harmonic current |
-
|
-
|
EN61000-3-2, EN61000-3-3
|
-
|
| EMS immunity |
-
|
-
|
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level criteria A
|
-
|
| SFP Speed DIP-Switch |
| DIP-Switch 1/2 |
DIP-Switch 1 (ON) and DIP-Switch 2 (ON) - SFP speed setting to 100Mbps DIP-Switch 1 (OFF) and DIP-Switch 2 (OFF) - SFP speed setting to 1000Mbps
|
-
|
-
|
-
|
| Technology |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3ab for 1000Base-T, IEEE 802.3x for Flow control, 802.3at PoE specyfication
|
-
|
-
|
-
|
| MAC Table |
1024 MAC addresses
|
-
|
-
|
-
|
| Processing |
Store-and-Forward
|
-
|
-
|
-
|
| Warranty |
| Warranty period |
5 years |
-
|
-
|
-
|
| Net Price |
432.00 USD |
9.41 USD |