| Unmanaged switch, 4x 10/1000 RJ-45 PoE, 1x 10/1000 RJ-45, 1x 1000 SFP socket, slim housing (ORing IGPS-1411GTP-24V) |
Modular crimping tool 4p+6p+8p (AT-2008R) |
Power supply 40W 24VDC, mini, DIN TS35 (Mean Well MDR-40-24) |
Modular crimping tool 8p (AT-L2182R) |
Managed switch, 22x 10/1000 RJ-45 PoE + 2x 10/100/1000 COMBO Ports with SFP + 2 slide-in SFP slots, O/Open-Ring <30ms, 19" (ORing RGPS-92222GCP-NP-LP) |
| Purpose |
-
|
modular plugs RJ50 (10p), modular computer plugs RJ45 (8p8c), modular telephone plugs (6p6c; 6p4c; 6p2c), 6p6c modular DEC type plugs, RJ9 modular headphone plugs (4p4c; 4p2c)
|
-
|
RJ45 modular computer plugs (8p8c)
|
-
|
| Additional functions |
-
|
Cutter and stripper for flat wires, inbuilt return block mechanism.
|
-
|
cutter and wire stripper, arm return lock
|
-
|
| Replaceable blades |
-
|
yes
|
-
|
yes
|
-
|
| Arms length |
-
|
20.3 cm
|
-
|
-
|
-
|
| Packaging |
-
|
-
|
-
|
Blister pack |
-
|
| Packagnig |
-
|
Blister pack |
-
|
-
|
-
|
| DIP-Switch |
| DIP-Switch 1 |
Power-1 failed warning - (ON) enable, (OFF) disable
|
-
|
-
|
-
|
-
|
| DIP-Switch 2 |
Power-2 failed warning - (ON) enable, (OFF) disable
|
-
|
-
|
-
|
-
|
| Environment |
| Working temperature |
-
|
-
|
-20°C ÷ 70°C
|
-
|
-
|
| Working humidity |
-
|
-
|
20÷90% RH non-condensing
|
-
|
-
|
| Storage temperature |
-
|
-
|
-40°C ÷ 85°C
|
-
|
-
|
| Storage Humidity |
-
|
-
|
10÷95% RH
|
-
|
-
|
| Temperature coefficient |
-
|
-
|
±0.03%/°C (0÷50°C)
|
-
|
-
|
| Vibration (component) |
-
|
-
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
-
|
-
|
| Vibration (mounting) |
-
|
-
|
compliance to IEC60068-2-6
|
-
|
-
|
| Environmental |
| Storage Temperature |
-40÷85°C (-40÷185°F)
|
-
|
-
|
-
|
-40÷85°C(-40÷185°F)
|
| Operating Temperature |
-40÷60°C (-40÷140°F)
|
-
|
-
|
-
|
-40÷60°C (-40÷140°F)
|
| Operating Humidity |
5%÷95% Non-condensing
|
-
|
-
|
-
|
5%÷95% Non-condensing
|
| Fault contact |
| Relay |
Relay output to carry capacity of 1A at 24VDC
|
-
|
-
|
-
|
-
|
| Function |
| DC OK signal relay contact rating (max.) |
-
|
-
|
30V/1A resistive
|
-
|
-
|
| Input |
| Voltage range |
-
|
-
|
85÷264VAC, 120÷370VDC
|
-
|
-
|
| Frequency range |
-
|
-
|
47÷63Hz
|
-
|
-
|
| Efficiency (typ.) |
-
|
-
|
88%
|
-
|
-
|
| AC current (typ.) |
-
|
-
|
1.1A/115VAC, 0.7A/230VAC
|
-
|
-
|
| Inrush current (typ.) |
-
|
-
|
30A/115VAC cold start, 60A/230VAC cold start
|
-
|
-
|
| Leakage current |
-
|
-
|
<1mA/240VAC
|
-
|
-
|
| LED Indicators |
| Power indicator |
Green - Power LED x 2
|
-
|
-
|
-
|
-
|
| 10/100/1000Base-T(X) RJ45 port indicator and PoE Indicator (P1÷P4) |
Green for port Link/Act., Green for power injected
|
-
|
-
|
-
|
-
|
| 10/100/1000Base-T(X) RJ45 port Indicator (P5) |
Green for port Link/Act., Amber for 100Mbps Indicator
|
-
|
-
|
-
|
-
|
| 100/1000Base-X SFP port indicator |
Green for port Link/Act.
|
-
|
-
|
-
|
-
|
| Ring Master indicator |
-
|
-
|
-
|
-
|
Green - indicates system operated in O-Ring Master mode
|
| O-Ring indicator |
-
|
-
|
-
|
-
|
Green - Indicate system operated in O-Ring mode, Green Blinking - Indicates that the Ring is broken.
|
| Fault indicator |
Amber - Indicate PWR1 or PWR2 failure
|
-
|
-
|
-
|
Amber - Indicates unexpected event occurred
|
| 10/100/1000TX RJ45 port indicator |
-
|
-
|
-
|
-
|
Green for port Link/Act
|
| Fiber port indicator |
-
|
-
|
-
|
-
|
Green for port Link/Act
|
| PoE indicator |
-
|
-
|
-
|
-
|
Green PoE LED x 24
|
| Others |
| MTBF |
-
|
-
|
min. 301700h MIL-HDBK-217F (25°C)
|
-
|
-
|
| Dimension (W x H x D) |
-
|
-
|
40mm x 90mm x 100mm
|
-
|
-
|
| Weight |
-
|
-
|
0.3kg |
-
|
-
|
| Output |
| DC Voltage |
-
|
-
|
24V
|
-
|
-
|
| Rated current |
-
|
-
|
1.7A
|
-
|
-
|
| Current Range |
-
|
-
|
0÷1.7A
|
-
|
-
|
| Rated Power |
-
|
-
|
40.8W
|
-
|
-
|
| Ripple & noise (max.) |
-
|
-
|
150mVp-p
|
-
|
-
|
| Voltage adjustment range |
-
|
-
|
24÷30V
|
-
|
-
|
| Voltage tolerance |
-
|
-
|
±1.0%
|
-
|
-
|
| Line regulation |
-
|
-
|
±1.0%
|
-
|
-
|
| Load regulation |
-
|
-
|
±1.0%
|
-
|
-
|
| Setup & rise time |
-
|
-
|
500ms & 30ms/230VAC at full load, 500ms & 30ms/115VAC at full load
|
-
|
-
|
| Hold up time (typ.) |
-
|
-
|
50ms/230VAC at full load, 20ms/115VAC at full load
|
-
|
-
|
| Physical Characteristic |
| Enclosure |
IP-30
|
-
|
-
|
-
|
IP-30
|
| Dimension (W x D x H) |
41 (W) x 94.9 (D) x 144.3(H) mm
|
-
|
-
|
-
|
431mm x 342mm x 44mm
|
| Weight |
580 g
|
-
|
-
|
-
|
5000 g
|
| Physical Ports |
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX (with PoE) |
-
|
-
|
-
|
-
|
22
|
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX with PoE+ (P.S.E.) |
4
|
-
|
-
|
-
|
-
|
| Gigabit Combo port with 10/100/1000Base-T(X) P.S.E. and 100/1000Base-X SFP ports |
-
|
-
|
-
|
-
|
2
|
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX |
1
|
-
|
-
|
-
|
-
|
| 100/1000Base-X SFP port |
1
|
-
|
-
|
-
|
-
|
| 100/1000 SFP |
-
|
-
|
-
|
-
|
4
|
| RS-232 Serial Console Port |
-
|
-
|
-
|
-
|
RS-232 in DB9 connector with console cable (115200bps, 8, N, 1)
|
| Power |
| Input power |
Dual DC inputs. 12~36VDC on 6-pin terminal block
|
-
|
-
|
-
|
100~240VAC with power socket
|
| Power supply |
-
|
-
|
-
|
-
|
450 Watts power supply included (320W power budget)
|
| Power consumption (typical) |
6.5W
|
-
|
-
|
-
|
37Watts (Typ.)
|
| Overload current protection |
present
|
-
|
-
|
-
|
present
|
| Reverse polarity protection |
not present
|
-
|
-
|
-
|
not present
|
| Protection |
| Overload |
-
|
-
|
105%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed
|
-
|
-
|
| Overvoltage |
-
|
-
|
31.2÷36V, protection type - shut down o/p voltage & re-power on to recover
|
-
|
-
|
| Regulatory approvals |
| EMI |
FCC Part 15, CISPR (EN55022) class A
|
-
|
-
|
-
|
FCC Part 15, CISPR (EN55022) class A
|
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
|
-
|
-
|
-
|
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
|
| Shock |
IEC60068-2-27
|
-
|
-
|
-
|
IEC60068-2-27
|
| Free Fall |
IEC60068-2-32
|
-
|
-
|
-
|
IEC60068-2-32
|
| Vibration |
IEC60068-2-6
|
-
|
-
|
-
|
IEC60068-2-6
|
| Safety |
EN60950-1
|
-
|
-
|
-
|
EN60950
|
| Safety & EMC |
| Safety standards |
-
|
-
|
UL508, UL60950-1, TUV EN60950-1, NEC class 2 / LPS
|
-
|
-
|
| Withstand voltage |
-
|
-
|
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC
|
-
|
-
|
| Isolation resistance |
-
|
-
|
I/P-O/P 100MΩ/500VDC 25°C 70%RH, I/P-FG 100MΩ/500VDC 25°C 70%RH, O/P-FG 100MΩ/500VDC 25°C 70%RH
|
-
|
-
|
| EMI conduction & radiation |
-
|
-
|
EN55011, EN55022 (CISPR22), EN61204-3 Class B
|
-
|
-
|
| Harmonic current |
-
|
-
|
EN61000-3-2, EN61000-3-3
|
-
|
-
|
| EMS immunity |
-
|
-
|
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level criteria A
|
-
|
-
|
| SFP Speed DIP-Switch |
| DIP-Switch 1/2 |
DIP-Switch 1 (ON) and DIP-Switch 2 (ON) - SFP speed setting to 100Mbps DIP-Switch 1 (OFF) and DIP-Switch 2 (OFF) - SFP speed setting to 1000Mbps
|
-
|
-
|
-
|
-
|
| Technology |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3ab for 1000Base-T, IEEE 802.3x for Flow control, 802.3at PoE specyfication
|
-
|
-
|
-
|
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3x for Flow control, IEEE 802.1D for STP (Spanning Tree Protocol), IEEE 802.1p for COS (Class of Service), IEEE 802.1Q for VLAN Tagging, IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol), IE |
| MAC Table |
1024 MAC addresses
|
-
|
-
|
-
|
8192 MAC addresses
|
| Priority Queues |
-
|
-
|
-
|
-
|
8
|
| Processing |
Store-and-Forward
|
-
|
-
|
-
|
Store-and-Forward
|
| Switching latency |
-
|
-
|
-
|
-
|
7 µs
|
| Switching bandwidth |
-
|
-
|
-
|
-
|
52 Gbps
|
| Max. Number of Available VLANs |
-
|
-
|
-
|
-
|
256
|
| IGMP multicast groups |
-
|
-
|
-
|
-
|
128/VLAN
|
| Port rate limiting |
-
|
-
|
-
|
-
|
User Define
|
| Security Features |
-
|
-
|
-
|
-
|
Enable/disable ports, MAC based port security, Port based network access control (802.1x), VLAN (802.1q ) to segregate and secure network traffic, Radius centralized password management, SNMPv3 encrypted authentication and access security
|
| Software Features |
-
|
-
|
-
|
-
|
STP/RSTP (IEEE 802.1D/w), Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units, TOS/Diffserv supported, Quality of Service (802.1p) for real-time traffic, VLAN (802.1Q) with VLAN tagging and GVRP supported, IGMP Snooping for multicast |
| Network Redundancy |
-
|
-
|
-
|
-
|
STP, RSTP, O-Ring, MSTP
|
| Warranty |
| Warranty period |
5 years |
-
|
-
|
-
|
5 years |
| Net Price |
432.00 USD |
9.41 USD |
21.70 USD |
10.20 USD |
1 850.00 USD |