| [-]remove#09191 |
[-]remove#08396 |
[-]remove#08397 |
| Router Mesh Halo H50G 3-pack, AC1900 (TP-Link Mercusys Halo H50G(3-pack)) |
Power supply 120W 24VDC, DIN TS35, P.F.C. (Mean Well SDR-120-24) |
Power supply 120W 48VDC, DIN TS35, P.F.C. (Mean Well SDR-120-48) |
| Standards |
IEEE 802.11 ac/n/a 5 GHz, IEEE 802.11 b/g/n 2,4 GHz
|
-
|
-
|
| Ports |
3 x 10/100/1000 Mb/s ports per Halo unit (WAN/LAN auto-sensing)
|
-
|
-
|
| Button |
1 Reset button
|
-
|
-
|
| Frequency range |
2.4 GHz and 5 GHz
|
-
|
-
|
| Signal Rate |
600 Mbps on 2.4 GHz, 1300 Mbps on 5 GHz
|
-
|
-
|
| EIRP |
CE <20 dBm (2,4 GHz) <23 dBm (5 GHz)
|
-
|
-
|
| Wireless Security |
WPA2-PSK + AES
|
-
|
-
|
| Wireless Functions |
Enable/Disable Wireless Radio, Wireless Statistics
|
-
|
-
|
| Mesh protocol |
802.11k/v
|
-
|
-
|
| WAN Type |
Dynamic IP/Static IP/PPPoE/PPTP/L2TP
|
-
|
-
|
| Management |
Access Control, Local Management, Remote Management
|
-
|
-
|
| DHCP |
Server, Address Reservation, DHCP Client List
|
-
|
-
|
| Port Forwarding |
Virtual Server, UPnP, DMZ, Port Triggering
|
-
|
-
|
| Protocols |
IPv4, IPv6
|
-
|
-
|
| Guest Network |
2.4 GHz Guest Network, 5 GHz Guest Network
|
-
|
-
|
| Dimensions |
3.5 × 3.5 × 3.5 in (88 × 88 × 88 mm)
|
-
|
-
|
| Operating Temperature |
0°C~40°C (-32℉~104℉)
|
-
|
-
|
| Storage Temperature |
-40℃~70℃ (-40℉~158℉)
|
-
|
-
|
| Operating Humidity |
10%~90% non-condensing
|
-
|
-
|
| Storage Humidity |
5%~90% non-condensing
|
-
|
-
|
| Package Contents |
3 Halo H50G units, 3 Power Adapters, 1 RJ45 Ethernet Cable, 1 Quick Installation Guide |
-
|
-
|
| Environment |
| Working temperature |
-
|
-25°C ÷ 70°C
|
-25°C ÷ 70°C
|
| Working humidity |
-
|
20÷95% RH non-condensing
|
20÷95% RH non-condensing
|
| Storage temperature |
-
|
-40°C ÷ 85°C
|
-40°C ÷ 85°C
|
| Storage Humidity |
-
|
10÷95% RH
|
10÷95% RH
|
| Temperature coefficient |
-
|
±0.03%/°C (0÷50°C)
|
±0.03%/°C (0÷50°C)
|
| Vibration (component) |
-
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
| Vibration (mounting) |
-
|
compliance to IEC60068-2-6
|
compliance to IEC60068-2-6
|
| Input |
| Voltage range |
-
|
88÷264VAC, 124÷370VDC
|
88÷264VAC, 124÷370VDC
|
| Frequency range |
-
|
47÷63Hz
|
47÷63Hz
|
| Power factor (typ.) |
-
|
0.93/230VAC at full load, 0.96/115VAC at full load
|
0.93/230VAC at full load, 0.96/115VAC at full load
|
| Efficiency (typ.) |
-
|
91%
|
90.5%
|
| AC current (typ.) |
-
|
1.4A/115VAC, 0.7A/230VAC
|
1.4A/115VAC, 0.7A/230VAC
|
| Inrush current (typ.) |
-
|
35A/115VAC cold start, 70A/230VAC cold start
|
35A/115VAC cold start, 70A/230VAC cold start
|
| Leakage current |
-
|
<1mA/240VAC
|
<1mA/240VAC
|
| Others |
| MTBF |
-
|
min. 289900h MIL-HDBK-217F (25°C)
|
min. 289900h MIL-HDBK-217F (25°C)
|
| Dimension (W x H x D) |
-
|
40mm x 125,2mm x 113,5mm
|
40mm x 125,2mm x 113,5mm
|
| Weight |
-
|
0,67kg |
0,67kg |
| Output |
| DC Voltage |
-
|
24V
|
48V
|
| Rated current |
-
|
5A
|
2.5A
|
| Current Range |
-
|
0÷5A
|
0÷2.5A
|
| Rated Power |
-
|
120W
|
120W
|
| Ripple & noise (max.) |
-
|
100mVp-p
|
120mVp-p
|
| Voltage adjustment range |
-
|
24÷28V
|
48÷55V
|
| Voltage tolerance |
-
|
±1.0%
|
±1.0%
|
| Line regulation |
-
|
±0.5%
|
±0.5%
|
| Load regulation |
-
|
±1.0%
|
±1.0%
|
| Setup & rise time |
-
|
1500ms & 60ms/230VAC at full load, 3000ms & 40ms/115VAC at full load
|
1500ms & 60ms/230VAC at full load, 3000ms & 40ms/115VAC at full load
|
| Hold up time (typ.) |
-
|
20ms/230VAC at full load, 20ms/115VAC at full load
|
20ms/230VAC at full load, 20ms/115VAC at full load
|
| Protection |
| Overload |
-
|
110%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed
|
110%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed
|
| Overvoltage |
-
|
29÷33V, protection type - shut down o/p voltage & re-power on to recover
|
56÷65V, protection type - shut down o/p voltage & re-power on to recover
|
| Over temperature |
-
|
95°C ±5°C (TSW1) detect on heatsink of power transistor, protection type - shut down o/p voltage & re-power on to recover
|
95°C ±5°C (TSW1) detect on heatsink of power transistor, protection type - shut down o/p voltage & re-power on to recover
|
| Safety & EMC |
| Safety standards |
-
|
UL508, UL60950-1, TUV EN60950-1
|
UL508, UL60950-1, TUV EN60950-1
|
| Withstand voltage |
-
|
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC
|
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC
|
| Isolation resistance |
-
|
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC
|
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC
|
| EMI conduction & radiation |
-
|
EN55011, EN55022 (CISPR22), EN61204-3 Class B
|
EN55011, EN55022 (CISPR22), EN61204-3 Class B
|
| Harmonic current |
-
|
EN61000-3-2, EN61000-3-3
|
EN61000-3-2, EN61000-3-3
|
| EMS immunity |
-
|
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level criteria A
|
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level criteria A
|
| Net Price |
111.00 USD |
56.70 USD |